48Vdc 120Vac 1-6KVA High Frequency Pure Sine Wave inverter

HOT PRODUCTS > Telecom Power Inverter > 48Vdc 120Vac 1-6KVA High Frequency Pure Sine Wave inverter

48Vdc 120Vac 1-6KVA High Frequency Pure Sine Wave inverter

DC Input Range: 40~60vdc;
Bypass Input:170~270vac;
AC output: 220VAC(±10V) Can be Adjustable On the LCD Display;
Output Voltage Precision(V):220Vac ±1.5%
Efficiency:>80%
Communication Interface:Rs232& Rs485 and Optional SNMP
shared:
48Vdc/120vac-1kva 48Vdc/120vac-2kva 48Vdc/120vac-3kva 48Vdc/120vac-4kva 48Vdc/120vac-5kva 48Vdc/120vac-6kva


  Product Description  

The sine wave inverter is especially designed and produced for the enterprises in electrical power system and post and telecommunication industries according to their actual requirements under the condition of not only considering the spatial installation size and the automation and networking requirements for the inverter management in IT age, but also considering the influence of the noise on the personnel in offices or in machine rooms.



The inverter of this series employs advanced SPWM and CPU control technology to realize precise control, isolated input and output, output soft start, safety, and high efficiency, good reliability and strong impact resistance to an inductive load. Not only with small volume, lightweight, beautiful appearance, convenient installation and maintenance, simple operation, low noise, low backward noise and no pollution, but also with the function of real-time data collection and multi-path remote communication, the products of this series can provide convenience for many system users to implement network management and remote control. Meanwhile, such inverter is not only applicable to the communication industry but also applicable to other occasions with high requirements for power supply quality, thus becoming the ideal selection of the power supply for office automation.


FEATURE 

True sine wave output (T.H.D < 3%);

Large 128*64 digital LCD  display data information4 led display working;

Standard 19” rack-Mount case;

5 Routes Dry contact for the system (DC input fault, AC input fault, overload information, by-pass information, and output fault);

RS232 and RS485  & Optional SNMP communication Port;

Power-on self-test, Soft output start;

Auto switch function: DC to AC, AC bypass, less than 5ms;

By-pass AC110V input filtering;

Real-time monitoring of the system operating status;

Audible and visual alarm;

Record the historical alarm message and can be queried;

Start auto restart while Ac or Dc is recovering;

Automatic start temperature control fan;

Build-in voltage regulator Stabilize AC voltage;

Maintenance bypass/DC available;

Protection: Short load protection, overload protection, battery over/under voltage protection, over current, over temperature;

Unattended operation: the system switches automatically to provide AC power to the load between the DC input and AC input;



26.jpg

 








1527578867431054908.png

Pure Sine Wave Output Voltage
This Type Inverter Application With Advanced PWM+SPWM  Technology, The Pure Sine Wave Output With Stable Frequency And Voltage, Filtered Noise And Low Distortion Factor.

1527588293867077815.png

Advanced DC-AC Electrical Isolation 

Technology

The Inverter With The Advanced DC-AC Electric Isolation Technology Can Really Implement The Completely Electric Isolation of DC And AC In All Circuits 

1527583913067026066.png

Advance Refleoted Noise Suppression 

Technology

This Product Does Not Mutually Intervene With The Communication Equipment Sharing The DC Cabinet. 





1527580542269059905.png

Two Working Model

 Mains Priority, In Case of Mains Fault, The Inverter Power Supply Automatically Switches To The Inverter Output.DC Priority, In Case of Battery Fault, The Inverter Power Supply Automatically Switches To The Bypass Output.



1527579547569000401.png

LCD+LED Real-Time Display
LED Display,Support RS232 & RS485 And SNMP Interface,Real-time Display And Remote Monitoring of Machine Working Status. Voltage, Current, Frequency, Capacity Rate, Temperature, Alarm Message, etc

1527575346339028098.png

Multiple Protection Function
 DC Input Inverse Connection Prevention, And DC Input Buffering Protection And Other Comprehensive Protection Measures For Overvoltage, Overload, Short Circuit, Over-Temperature, And Inverter Fault.





PRODUCT DISPLAY 







APPLICATION



PD家用逆變器連接圖示


   1. Telecom station/base/ Cable Equipment    7.City WIFI device  13. Fire Alarm Systems
   2. Communication Station    8. Emergency communication car  14. power utility System Control /field
   3. Computer data center    9. Railway & metro  15. power plant/station
   4. SCADA Networks and Data Equipment   10. Distributed Antenna Systems  16.Power monitoring system
   5. Radio Base stations/ Cell Sites   11. Marine & offshore  17.Solar power system
   6. Monitoring center room   12. Building Management Systems  18.Wind energy system








主站蜘蛛池模板: 日本精品一在线观看视频 | 国产精品亚洲欧美 | 国产一级精品高清一级毛片 | 亚洲精品xxx | 2019精品手机国产品在线 | 亚洲欧美婷婷 | 亚洲日本中文字幕永久 | 全国最大色成免费网站 | 亚洲天堂久久新 | 亚洲三级在线免费观看 | 触手系列精品集 | 欧美日韩一区二区三区免费 | 欧美激情一区二区三区视频 | 视频一区二区中文字幕 | 国产成人综合久久亚洲精品 | 久久久久久麻豆 | 精品视频入口 | www.av一区| 日韩特黄特色大片免费视频 | 久久综合丁香激情久久 | 久久99精品久久久久久 | 国产免费啪视频观看网站 | 极品美女高清视频在线观看 | 天堂网站在线观看 | 国产精品国产三级国产专不∫ | 精品一区二区三区高清免费观看 | 黄色免费观看网站 | 自拍一区在线观看 | 99精品国产自在现线免费下载 | 国产精品久久免费 | 久久这里只有精品6 | 久久青青草原精品国产不卡 | 国产区久久 | 亚洲激情在线观看 | a级日韩乱理伦片在线观看 a级片免费在线播放 | 伊人狼人在线 | 国产又色又爽又黄的网站在线一级 | 日韩精品福利在线 | 在线观看男女男免费视频 | 国产精品盗摄一区二区在线 | 国产成人免费a在线资源 |